CLINICAL CHEMISTRY ANALYZER CHL
Brochure
|
 |
OPTICAL SYSTEM· Principle: Monochromator by Interferential Filters.· Photometric range from –0.2 to 2.2 Abs· Spectral range: Range from 340 nm to 700 nm.· Filter Wheel of 9 positions (7 filters included): Automatic 340-405-420-505-546-578-670 nm· Bandwidth: 10 nm (±2)· Photometric Inaccuracy: £1% to 0,200 A and £0,5% to 2,000 A.· Linearity: up to 2,200 A.· Precision: CV £0,5% to 0,200 A and £0,1% to 2,000 A.· Photometric Noise: 0,001 A.· Light Source: Halogen lamp. (12V/20W).· Zero: Automatic.· Reading: Monochromatic and Bichromatic.· Detector: Silikon Photodiode. THERMOSTATIC CONTROL· Peltier system with programmable temperature from 23°C to 40°C in steps of 1°C.· Accuracy: 0,2°C. PRINTER· Thermal graphical printer· High Speed: 800 characters/sec.· Paper: Thermosensitive, 80 mm wide· Programming: Intensity printing control, with OFF/ON Printer DISPLAY· LCD display of 64 x 240 pixels CALCULATION MODES· Aborption/Contrentration· End Point with Factor or Standard· Enzyme Kinetics with Factor or Standard· Polygonal Multi-Standard (Calibration curve) KINETICS· Delta Determination.· Incubation Time: Programmable from 1 to 999 sec.· Interval time: Programmable from 1 to 999 sec.· No of Deltas: Programmable from 2 to 20
PROGRAMMING
· 75 Locations (Non Volatile Memory) to programme up to 75 different Tests (Open System)· Programming of the Laboratory Name· Programming of units· Programming of the Filter positions· Printer Control· Two washing modes, Fixed volume or Continuous· Biosystem test programmed in the first locations ELECTRONICS· Microprocessor H/510 of 8/16 bits to 10 Mhz· EPROM Memory up to 512 Kbyte· RAM Memory from 8 Kbytes to 32 Kbytes· EEPROM Memory of 8 Kbytes· Programmable Digital Logical Circuits· Electronics Circuit System: Designed as N.A.A.R. System· Calibration of the instrument by incorporated software COMPUTER CONNECTION· PC communication software POWER REQUIREMENTS· 115/230 VAC (10%)· 50/60 Hz· 855 VA DIMENSIONS & WEIGHT· (W x D x H): 387 x 337 x 150 mm· 9,5 kg CUVETTES AND TUBES· Flow cuvette (Micro).· Manual cuvettes (Macro,Semimicro and Micro)· Tubes (Ø 12mm) ASPIRATION SYSTEM· Peristaltic System with flow-thru cuvette, 18 µL· Pump stepper motor controled in low voltage
· Sipping Volume programmable from 100µL to 5mL
ORDER FORM
CLINICAL CHEMISTRY ANALYZER CHL
1 UNIT
|
Name
|
|
|
Institution
|
|
|
Address
|
|
|
City
|
|
|
State
|
|
|
Tel.
|
|
|
Fax
|
|
|
E-mail
|
|
|
Note
|
|
|
|
|
|
|
|
|
|